Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
JDS Commun ; 1(1): 10-14, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36340428

RESUMO

The aim of this study was to evaluate the diagnostic accuracy of 5 indirect methods that may be used in veterinary practices to assess the success of maternal immunoglobulins transfer in neonatal calves. Blood samples (n = 245) were collected from 2- to 6-d-old calves. Serum immunoglobulin concentrations were determined by radial immunodiffusion. Serum total protein and albumin concentrations and γ-glutamyl transferase activity were determined by veterinary practitioners using their own biochemistry analyzer. Globulin concentration was calculated. Veterinary practitioners were also asked to assess serum total protein using a digital Brix refractometer (%Brix) and an optical refractometer (g/L). Test sensitivity (Se) and specificity (Sp) were calculated using radial immunodiffusion as the reference standard, with failure of transfer of passive immunity defined as IgG <10.0 g/L. Receiver operating characteristics curves were created and optimal cutoff values for each of the 5 indirect measurement methods were selected based on the maximization of the Youden's J statistic. In this study, Globulin concentration yielded the highest accuracy to identify failure of transfer of passive immunity (Se = 89.4%; Sp = 89.3% at 34 g/L). For %Brix, the optimal combination of Se and Sp was at 8.4% Brix (Se = 86.5% and Sp = 83.8%). The use of an optical refractometer was associated with the lowest diagnostic accuracy (Se = 69.7% and Sp = 81.6% at 52 g/L). For γ-glutamyl transferase activity, the optimal cut-points were different for 2- to 3-d-old calves (Se = 87.5% and Sp = 87.8% at 393 IU/L) or 4- to 6-d-old calves (Se = 90.0% and Sp = 86.4% at 254 IU/L). Because it does not require any specialized laboratory equipment, digital Brix refractometer can be a valuable and inexpensive tool for on-farm use, to help producers and veterinary practitioners in their calf health management programs.

3.
Animal ; 10(2): 230-7, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26776495

RESUMO

High-immune quality colostrum (IgG1 concentration ⩾50 g/l) is crucial for the health and development of the young calf. Studies on colostrum quality tend to focus on external factors such as breed, parity or dry period length, but few have focused on within-cow variations. Here we ran experiments to gain a deeper insight into within-cow variation in IgG1 concentrations in dairy cow colostrum. Trials were performed in an experimental farm, located in the Western part of France. Colostrum from each quarter and a composite sample (mix of four quarters) were concomitantly collected on 77 Holstein dairy cows just after calving to assess the influence of sample type on IgG1 concentrations. Variation in IgG1 concentrations during the first milking was studied on samples from nine cows collected every minute from the start of milking. Repeatability of colostral IgG1 concentration was estimated from 2009 and 2010 data on 16 healthy cows. IgG1 concentrations were tested using a radial immunodiffusion method. Sensitivity and specificity were similar regardless of sample type tested (individual quarter or composite milk). Mean average IgG1 concentration was 54.1 g/l in composite colostrum, and was significantly higher in hind quarter teats (56.2 g/l) than front quarter teats (53.1 g/l). Average IgG1 concentration did not change significantly during colostrum milking, and the variations observed (15% or less) were likely due to the laboratory method (CV 15%). IgG1 concentrations in dam colostrum increased slightly from 2009 to 2010 due to BW and parity effects. In 56% of cases, colostrum quality could have been assessed on either individual or composite colostrum samples collected at any time during the first milking without affecting the reliability of the measurement. However, in other cases, differences were significant enough to mean that estimates of average IgG1 concentration in colostrum from any one quarter would not be reliable. It is concluded that colostrum quality, from an IgG1 concentration point of view, could be assessed with a composite sample taken at any time during the first milking.


Assuntos
Bovinos/imunologia , Colostro/imunologia , Imunoglobulina G/análise , Animais , Peso Corporal , Bovinos/fisiologia , Feminino , França , Imunodifusão/métodos , Imunodifusão/veterinária , Imunoglobulina G/imunologia , Lactação/imunologia , Lactação/fisiologia , Glândulas Mamárias Animais/imunologia , Leite/imunologia , Leite/metabolismo , Paridade , Gravidez , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...